-40%
UPS 14/18L Dental Autoclave Medical Steam Sterilizer Sterilization Automatically
$ 279.31
- Description
- Size Guide
Description
Ship from USA to USA14L Dental Steam Autoclave Sterilizer Medical Sterilization S/S 304 Lab
Description:
Chamber capacity:Ø25×D28CM (Ø9.84×D11.02inch)
Inside capacity:14 Liter
Material:Stainless steel #304
Outside Size :46.5*35*36 CM
Packing Size :51*39*40 CM
G.W:15KGS
Sterilizer temperature:121℃
Sterilize pressure:0.12Mpa
Sterilize time:25Min
Power:900W
AC110V/8A
AC220V/4A
Auto supply water system: Manual give the water
Safety valve: automatic discharge in excess of standard value
Temp and Press display:Pressure gauge
Disinfection principle:Uses the vapor power emissions cold air / 2 times
Operation Steps:
1.Plug in the power cord
2.Shut exhaust needle valve in the Close (clockwise)°
3.Adding about 800 ml of distilled water. Close the door cover, tight the rotate handle
4. Start the timer knob to 121 ℃ position. Sterilization is working.
5.Sterilization is complete, please be sure to open the exhaust needle valve firstly (inverse clock direction)
6.Wait for the pressure gauge pointer to zero, opened the door cover
Caution:
Every time sterilization, must add about 800 ml of distilled water
Use a separate socket (confirm the socket of the output voltage)
Pressure gauge pointer in the red areas, please be sure to first Open the exhaust steam of the needle valve
Packing:
main unit 1pc
Standard accessories:
Plate 3pcs ( Size:21*15.5*2 cm)
Shelf 1pc
Take Plate tool 1pc steam exhaust pipe 1pc(1 meter length)
++++++++++++++++++++++++++++++++++++++
18L Dental Autoclave Steam Sterilizer Medical Sterilization FDA CE Certification
Description:
Chamber capacity:Ø25×D35CM (Ø9.84×D13.78inch)
Inside capacity:18 Liter
Material:Stainless steel #304
Outside Size(L*W*H) :56*39*36 CM
Packing Size(L*W*H) :64*46*41 CM
G.W:25.5KGS
Sterilizer temperature/pressure:121℃/0.12Mpa; 134℃/0.22Mpa
Sterilize time:25Min/6Min
Power:900W
AC110V/8A
AC220V/4A
Auto supply water system: Manual give the water
SAFETY : Heating-over protection ; safety valve
Safety equipment:
1.Pressure adjustment: adjust the inter pressure, if over standard value
automatic vent
2. Avoild overheat protect device: when inter temperature overheat, power break electric current automatically.
Temp and Press display :Led several windows
Disinfection principle:Uses the vapor power emissions cold air / 2 times
Caution:
1.After the completion of disinfection,please to wait for 10 minutes.
Pressure Gauge in red area. Do not rotate handle, open the steam discharge valve firstly.
2.Before each use,must supply water 800ml of distilled water .
3.Please close steam discharge valve before the disinfection.
4.Do not use any corrosive or chemical water as the disinfection.
5.Do not share the same electricoutllet with other electrical apparetus.
6.Please pay attention to correct voltage and frequency.
7.Connect steam exhaust pipe with the steam vent,before operation.
Packing:
Main unit 1pc
Standard accessories:
Plate 3pcs
Shelf 1pc
Take Plate tool 1pc
Steam exhaust pipe 1pc
FDA Statement
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.