-40%

2P DC Direct-Current 600V Circuit breaker MCB C Curve Single Pole Fuse for PV

$ 9.23

Availability: 129 in stock
  • Voltage Rating (DC): DC 600V
  • Number of Poles: 2P
  • Standard: IEC60947, IEC60898
  • Mounting: 35mm din rail
  • Breaking Capacity: 6KA
  • Brand: TOMZN
  • Return shipping will be paid by: Buyer
  • Model Number: TOB1Z-63
  • Condition: New
  • MPN: Does Not Apply
  • Refund will be given as: Money Back
  • Item must be returned within: 30 Days
  • All returns accepted: Returns Accepted
  • Country/Region of Manufacture: China

    Description

    2P DC Direct-Current 600V Circuit breaker MCB C Curve Single Pole Fuse for PV
    Application
    TOBIZ-63 Series DC Miniature Circuit Breaker, apply to rating current 63A or less, Direct current rating voltage 250V and 600V. It is mainly used for the overloading and short circuit protection in DC distribution system Equipment and electric equipment. It can be widely used in electric, post, traffic, mining enterprise and different kinds of fields. Products according IEC60898-1, GB14048.2 standard.
    Characteristic
    TOBIZ-63 DC circuit breaker is made up of case, operation mechanism, thermal overloading trip, electromagnetic trip contact system, arc system etc. It has overloading and short circuit protection, unique-design structure and strong permanent magnetism arc system make the product has 6KA short circuit capability. Long mechanical life over 20000 times and beautiful shape. It can be connected with din rail named TH35-7.5 standard stainless type and has the below personality: the handle is designed on the top of the front, people will feel safe and comfortable when operating. When connecting, pay attention to "+, -" poles; The power goes in from the top and comes out from the underside which is applied with power entrance character. Convenient for installation and saving cables. It is used for 440V circuit 3 poles circuit breaker to connect front loop for two poles serial connection.
    B Curve (3-5In) protection for people and big length cables in TN and IT systems
    C Curve (5-10In) protection for resistive and inductive loads with low inrush current.
    D Curve (10-14In) protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers, breakdown lamps)
    Crust grade rating current Imm(A)
    Pole
    Rating voltage(V)
    Rating current In(A)
    Rated limit short circuit capability
    Instantaneous trip type
    Breaking current Icu(A)
    Time (ms)
    63A
    1
    DC ~250V
    1. 2. 3. 4. 5. 6. 10. 15. 16. 20. 25. 32. 40. 50. 63
    6000
    10
    C
    2
    DC ~600V
    6000
    3
    DC ~800V
    4
    DC ~1000V
    Before You Order
    It's easy to make mistakes when ordering, so please double-check the details. All the information you require should be on this page,
    however if you have questions not already answered here, please contact us
    . It's better to check than to discover a problem after the item have arrived!
    POSTAGE
    Please note that for some items in our store we not provide combined shipping!
    Time of arriving
    Approximately =>
    30 - 60 working days
    Package included
    1pc* DC Circuit Breaker
    Thanks for your attention!!!